PULS
ML50.109
AC/DC Power supply unit (PSU) / converter with NEC Class 2 + conformal coating - PULS (MiniLine) - 24Vdc-28Vdc (adjustable) / 2.1A / 50W output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 82Vdc-380Vdc (100Vdc / 110Vdc /120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - DIN rail mounting (45mm width) - equivalent to #ML50109
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
ML50.109
Online Price
$244.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
ML50.109
Description
AC/DC Power supply unit (PSU) / converter with NEC Class 2 + conformal coating - PULS (MiniLine) - 24Vdc-28Vdc (adjustable) / 2.1A / 50W output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 82Vdc-380Vdc (100Vdc / 110Vdc /120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - DIN rail mounting (45mm width) - equivalent to #ML50109
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
MiniLine series
Functions
AC/DC Power supply unit (PSU) / converter
Design
NEC Class 2
conformal coating
DC-OK rly. contact output
conformal coating
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
65Vac turn-ON voltage
55Vac shutdown voltage
65Vac turn-ON voltage
55Vac shutdown voltage
Supply voltage (DC)
82Vdc-380Vdc (100Vdc / 110Vdc /120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Type of network
Single-phase (1AC) or DC
Rated current
2.1A (at 24Vdc)
Rated power
50W
Output voltage (DC)
24Vdc-28Vdc (adjustable)
400mV turn-ON overshoot
400mV turn-ON overshoot
Connection type
spring-clamp connections
Protection functions
NTC (input inrush current limiter)
Efficiency
0.89 (230Vac input)
0.884 (120Vac input)
0.875 (100Vac input)
0.884 (120Vac input)
0.875 (100Vac input)
Net Width (mm)
45 mm
Mounting mode
DIN rail mounting
Dimensions
W45mm x H75mm x D91mm
Material
PC / ABS blend housing
Ambient air temperature for operation
-10...+70 °C
Chemical resistance
Resistant to harsh environment (conformal coated PCB)
Current consumption
17A max. inrush (at 120Vac input)
35A peak max. inrush (at 230Vac input)
35A peak max. inrush (at 230Vac input)
Power dissipation/losses
6.2 W
Power factor (cos phi)
0.52
Manufacturer product status
Commercialized
Equivalent to
ML50109
Capacitance
(output stage) 1600 μF
Compliant with standard(s)
SN 29500
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
NEC CLASS 2
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
NEC CLASS 2
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
A compact size; light weight; simple mounting onto the DIN-rail and the utilization of only quality components are what makes the MiniLine power supplies so easy to use and install within seconds.
A rugged electrical and mechanical design as well as a high immunity against electrical disturbances on the mains provides reliable output power.
This offers superior protection for equipment which is connected to the public mains network or is exposed to a critical industrial environment.
A rugged electrical and mechanical design as well as a high immunity against electrical disturbances on the mains provides reliable output power.
This offers superior protection for equipment which is connected to the public mains network or is exposed to a critical industrial environment.
Electrical durability
54kh (min; at +40°C) / 54 000 hours
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
2613kh (at +40°C) / 2 613 000h
Time delay
32ms start-up delay (100-230Vac input)
33-48ms rise time (nominal input; constant full current load; 0mF load capacitance)
45-60ms rise time (nominal input; constant full current load; 2mF load capacitance)
33-48ms rise time (nominal input; constant full current load; 0mF load capacitance)
45-60ms rise time (nominal input; constant full current load; 2mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - ML50-109 - Datasheet.pdf | 01 Oct 2021 | English (US) |