PULS
QS3.241
AC/DC Power supply unit (PSU) / converter - 50% power reserve - PULS (DIMENSION Q-series) - 3A (at 28Vdc) - 24Vdc-28Vdc (adjustable) / 3.4A / 84W output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-375Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - DIN rail mounting (32mm width) - equivalent to #QS3241
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
QS3.241
Online Price
$265.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
QS3.241
Description
AC/DC Power supply unit (PSU) / converter - 50% power reserve - PULS (DIMENSION Q-series) - 3A (at 28Vdc) - 24Vdc-28Vdc (adjustable) / 3.4A / 84W output - with spring-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-375Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - DIN rail mounting (32mm width) - equivalent to #QS3241
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
Q-series
Functions
AC/DC Power supply unit (PSU) / converter
50% power reserve
50% power reserve
Design
50% power reserve
DC-OK rly. contact output
DC-OK rly. contact output
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
61Vac turn-ON voltage
58Vac shutdown voltage
61Vac turn-ON voltage
58Vac shutdown voltage
Supply voltage (DC)
88Vdc-375Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Display
"DC-OK" LED
Type of network
Single-phase (1AC) or DC
Rated current
3.4A (at 24Vdc)
3A (at 28Vdc)
3A (at 28Vdc)
Rated power
80W (at 24V)
84W (at 28V)
120W short-term (for 4s)
84W (at 28V)
120W short-term (for 4s)
Output voltage (DC)
24Vdc-28Vdc (adjustable)
100mV turn-ON overshoot
100mV turn-ON overshoot
Hold time
174ms (buffer time at 230Vac input)
41ms (buffer time at 120Vac input)
41ms (buffer time at 120Vac input)
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (34Vdc typ. / 36Vdc max.)
active (input inrush current limiter)
Overload / short-circuit current -- min. 3.5A (max. 4.2A) load impedance <25mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
active (input inrush current limiter)
Overload / short-circuit current -- min. 3.5A (max. 4.2A) load impedance <25mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 35V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.9 (230Vac input)
0.887 (120Vac input)
0.871 (100Vac input)
0.887 (120Vac input)
0.871 (100Vac input)
Net Width (mm)
32 mm
Mounting mode
DIN rail mounting
Dimensions
W32mm x H124mm x D102mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
7A peak max. inrush (at 120Vac input)
13A peak max. inrush (at 230Vac input)
13A peak max. inrush (at 230Vac input)
Power dissipation/losses
(230Vac input; full output load) 9.1 W
(120Vac input; full output load) 10.4 W
(120Vac input; full output load) 10.4 W
Power factor (cos phi)
(230Vac input) 0.47
(120Vac input) 0.53
(120Vac input) 0.53
Manufacturer product status
Commercialized
Equivalent to
QS3241
Capacitance
(output stage) 1500 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
AC 100-240V Wide-range input
Width only 32mm
Efficiency up to 90%
150% (120W) Peak Load Capability
Easy fuse tripping due to high overload current
Negligible low Inrush Current Surge
Short-term Operation down to 60Vac and up to 300Vac
Full power between -25°C and +60°C
Quick-connect Spring-clamp Terminals
3 Year warranty
The most outstanding features of this Dimension Q Series DIN-rail power supply are the high efficiency and the small size which are achieved by a synchronous rectification and further novel design details. The QSeries is part of the Dimension family existing alongside the lower featured C-Series. With short-term peak power capability of 150% and built-in large sized output capacitors these features help start motors charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager a wide range input voltage design and virtually no input inrush current make installation and usage simple. Diagnostics are easy due to a green DC-ok LED and red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.
Width only 32mm
Efficiency up to 90%
150% (120W) Peak Load Capability
Easy fuse tripping due to high overload current
Negligible low Inrush Current Surge
Short-term Operation down to 60Vac and up to 300Vac
Full power between -25°C and +60°C
Quick-connect Spring-clamp Terminals
3 Year warranty
The most outstanding features of this Dimension Q Series DIN-rail power supply are the high efficiency and the small size which are achieved by a synchronous rectification and further novel design details. The QSeries is part of the Dimension family existing alongside the lower featured C-Series. With short-term peak power capability of 150% and built-in large sized output capacitors these features help start motors charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager a wide range input voltage design and virtually no input inrush current make installation and usage simple. Diagnostics are easy due to a green DC-ok LED and red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.
Electrical durability
(at 40°C; 3.4A output; 1AC 120Vac input) 62000 hours
(at 40°C; 3.4A output; 1AC 230Vac input) 79000 hours
(at 40°C; 1.7A output; 1AC 120Vac input) 126000 hours
(at 40°C; 1.7A output; 1AC 230Vac input) 114000 hours
(at 25°C; 3.4A output; 1AC 120Vac input) 177000 hours
(at 25°C; 3.4A output; 1AC 230Vac input) 224000 hours
(at 40°C; 3.4A output; 1AC 230Vac input) 79000 hours
(at 40°C; 1.7A output; 1AC 120Vac input) 126000 hours
(at 40°C; 1.7A output; 1AC 230Vac input) 114000 hours
(at 25°C; 3.4A output; 1AC 120Vac input) 177000 hours
(at 25°C; 3.4A output; 1AC 230Vac input) 224000 hours
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
1265000h (at 40°C; 120Vac input; MTBF SN 29500 IEC 61709)
1451000h (at 40°C; 230Vac input; MTBF SN 29500 IEC 61709)
2155000h (at 25°C; 120Vac input; MTBF SN 29500 IEC 61709)
2436000h (at 25°C; 230Vac input; MTBF SN 29500 IEC 61709)
631000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F)
643000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F)
889000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F)
912000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F)
1451000h (at 40°C; 230Vac input; MTBF SN 29500 IEC 61709)
2155000h (at 25°C; 120Vac input; MTBF SN 29500 IEC 61709)
2436000h (at 25°C; 230Vac input; MTBF SN 29500 IEC 61709)
631000h (at 40°C; 120Vac input; MTBF MIL HDBK 217F)
643000h (at 40°C; 230Vac input; MTBF MIL HDBK 217F)
889000h (at 25°C; 120Vac input; MTBF MIL HDBK 217F)
912000h (at 25°C; 230Vac input; MTBF MIL HDBK 217F)
Time delay
330-360ms start-up delay (100-230Vac input)
5-7ms rise time (nominal input; constant full current load; 0mF load capacitance)
20-22ms rise time (nominal input; constant full current load; 3.4mF load capacitance)
5-7ms rise time (nominal input; constant full current load; 0mF load capacitance)
20-22ms rise time (nominal input; constant full current load; 3.4mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - QS3-241-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |