PULS
QTD20.241
Power supply unit (PSU) / DC/DC-Converter - intermediate DC-bus and galvanic isolation - 25% power reserve - PULS (DIMENSION Q-series) - 17.5A (at 28Vdc) - 24Vdc-28Vdc (adjustable) / 20A output - with spring-clamp connections - DC input (384Vdc-672Vdc (500Vdc / 575Vdc / 600Vdc nom.)) - DIN rail mounting (65mm width) - equivalent to #QTD20241
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
QTD20.241
Online Price
$740.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
QTD20.241
Description
Power supply unit (PSU) / DC/DC-Converter - intermediate DC-bus and galvanic isolation - 25% power reserve - PULS (DIMENSION Q-series) - 17.5A (at 28Vdc) - 24Vdc-28Vdc (adjustable) / 20A output - with spring-clamp connections - DC input (384Vdc-672Vdc (500Vdc / 575Vdc / 600Vdc nom.)) - DIN rail mounting (65mm width) - equivalent to #QTD20241
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
DIMENSION series
Sub-range name
Q-series
Functions
Power supply unit (PSU) / DC/DC-Converter
25% power reserve
25% power reserve
Design
intermediate DC-bus and galvanic isolation
25% power reserve
DC-OK rly. contact output
25% power reserve
DC-OK rly. contact output
Supply voltage (DC)
384Vdc-672Vdc (500Vdc / 575Vdc / 600Vdc nom.)
450Vdc turn-ON voltage
325Vdc shutdown voltage
450Vdc turn-ON voltage
325Vdc shutdown voltage
Display
"DC-OK" LED
Type of network
DC
Rated current
20A (at 24Vdc)
17.5A (at 28Vdc)
12W/+60°C...+70°C (derating)
17.5A (at 28Vdc)
12W/+60°C...+70°C (derating)
Rated power
480W (at 24Vdc and 28Vdc)
Output voltage (DC)
24Vdc-28Vdc (adjustable)
500mV turn-ON overshoot
500mV turn-ON overshoot
Hold time
22ms (buffer time at 600Vdc input)
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (32Vdc typ. / 35Vdc max.)
Overload / short-circuit current -- min. 20A (max. 23A) load impedance <50mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 34V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the DC/DC converter. It does not matter whether the DC/DC converter is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Overload / short-circuit current -- min. 20A (max. 23A) load impedance <50mΩ
Series / parallel operation -- Power supplies can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (+/-100mV) in Single use mode with the same load conditions on all units
Back-feeding loads max. 34V -- The unit is resistant and does not show malfunctioning when a load feeds back voltage to the DC/DC converter. It does not matter whether the DC/DC converter is ON or OFF. The absorbing energy can be calculated according to the built-in large sized output capacitor.
Efficiency
0.95 (600Vdc input)
Net Width (mm)
65 mm
Mounting mode
DIN rail mounting
Dimensions
W65mm x H124mm x D127mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Current consumption
3A peak max. inrush (at 600Vdc input)
Power dissipation/losses
(600Vdc input; full output load) 25.5 W
Application type
For galvanic isolation in mobile applications e.g. ships or forklifts
Manufacturer product status
Commercialized
Equivalent to
QTD20241
Capacitance
(output stage) 950 μF
Compliant with standard(s)
CE marking
UL 508
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-4 Emission for industrial environments
UL 508
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-4 Emission for industrial environments
Benefits
DC 600V Input
Optimized for Intermediate DC-bus of Drive Systems
2 Input Fuses for DC 600V included
95% Full Load and Excellent Partial Load Efficiencies
Width only 65mm Weight only 890g
25% BonusPower 600W for up to 4s
Active Filtering of Input Transients
Full power between -25°C and +60°C
Extremely Low Input Inrush Current Surge
Reverse input polarity protection
DC-OK relay contact
Quick-connect Spring-clamp Terminals
3 Year warranty
Modern machines typically use maintenance-free AC motors which are controlled by frequency converters or servo amplifiers. Such devices have an intermediate DC-bus where all individual drives are connected. The QTD20 DC/DC converter can be connected directly to the intermediate DC-bus. In case of a mains failure the QTD20 utilizes the power from the DC-bus capacitors which are charged from the kinetic energy of the motor until the motor has come to a complete stop. The intermediate DC-bus is usually unfiltered and have high EMI noise so the QTD20 has a very robust input stage and an appropriate input filter included. Additionally the QTD20 is UL 508 approved and is equipped with input fuses which are rated and tested for 600Vdc applications.
Optimized for Intermediate DC-bus of Drive Systems
2 Input Fuses for DC 600V included
95% Full Load and Excellent Partial Load Efficiencies
Width only 65mm Weight only 890g
25% BonusPower 600W for up to 4s
Active Filtering of Input Transients
Full power between -25°C and +60°C
Extremely Low Input Inrush Current Surge
Reverse input polarity protection
DC-OK relay contact
Quick-connect Spring-clamp Terminals
3 Year warranty
Modern machines typically use maintenance-free AC motors which are controlled by frequency converters or servo amplifiers. Such devices have an intermediate DC-bus where all individual drives are connected. The QTD20 DC/DC converter can be connected directly to the intermediate DC-bus. In case of a mains failure the QTD20 utilizes the power from the DC-bus capacitors which are charged from the kinetic energy of the motor until the motor has come to a complete stop. The intermediate DC-bus is usually unfiltered and have high EMI noise so the QTD20 has a very robust input stage and an appropriate input filter included. Additionally the QTD20 is UL 508 approved and is equipped with input fuses which are rated and tested for 600Vdc applications.
Electrical durability
(at 25°C; 10A output; 600Vdc input) 220000 hours
(at 40°C; 10A output; 600Vdc input) 78000 hours
(at 25°C; 20A output; 600Vdc input) 119000 hours
(at 40°C; 20A output; 600Vdc input) 42000 hours
(at 40°C; 10A output; 600Vdc input) 78000 hours
(at 25°C; 20A output; 600Vdc input) 119000 hours
(at 40°C; 20A output; 600Vdc input) 42000 hours
Ripple
100mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
801000h (at 25°C; 600Vdc input; MTBF SN 29500 IEC 61709)
446000h (at 40°C; 600Vdc input; MTBF SN 29500 IEC 61709)
267000h (at 25°C; 600Vdc input; MTBF MIL HDBK 217F)
204000h (at 40°C; 600Vdc input; MTBF MIL HDBK 217F)
446000h (at 40°C; 600Vdc input; MTBF SN 29500 IEC 61709)
267000h (at 25°C; 600Vdc input; MTBF MIL HDBK 217F)
204000h (at 40°C; 600Vdc input; MTBF MIL HDBK 217F)
Time delay
35s start-up delay (600Vdc input)
70ms rise time (nominal input; constant full current load; 0mF load capacitance)
110ms rise time (nominal input; constant full current load; 20mF load capacitance)
70ms rise time (nominal input; constant full current load; 0mF load capacitance)
110ms rise time (nominal input; constant full current load; 20mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - QTD20-241 - Datasheet.pdf | 01 Oct 2021 | English (US) |