PULS
UB10.242
DC/DC Uninterruptible Power Supply (UPS) control module with external batt. + batt. temperature control - 50% power reserve - PULS (DIMENSION UB-series) - 15A (in bfr. mode less than 5s full output voltage) - 22.5Vdc (regulated) in bfr. mode / 10A / 360W output - with spring-clamp connections - DC input (22.5Vdc-30Vdc (24Vdc nom.)) - DIN rail mounting (mm width) - equivalent to #UB10242
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
UB10.242
Online Price
$550.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
UB10.242
Description
DC/DC Uninterruptible Power Supply (UPS) control module with external batt. + batt. temperature control - 50% power reserve - PULS (DIMENSION UB-series) - 15A (in bfr. mode less than 5s full output voltage) - 22.5Vdc (regulated) in bfr. mode / 10A / 360W output - with spring-clamp connections - DC input (22.5Vdc-30Vdc (24Vdc nom.)) - DIN rail mounting (mm width) - equivalent to #UB10242
Specifications
Primary brand
PULS
Main function
Uninterruptible Power Supply (UPS)
Product series / family name
DIMENSION series
Sub-range name
UB-series
Functions
DC/DC Uninterruptible Power Supply (UPS) control module
Design
external batt.
batt. temperature control
50% power reserve
Green status LED
batt. temperature control
50% power reserve
Green status LED
Supply voltage (DC)
22.5Vdc-30Vdc (24Vdc nom.)
Display
"Status" LED
Type of network
DC
Rated current
10A (at 22.5Vdc)
15A (in bfr. mode less than 5s full output voltage)
Output 1 in normal mode = 15A
Output 1 in buffer mode = 10A/15A (360W)
15A (in bfr. mode less than 5s full output voltage)
Output 1 in normal mode = 15A
Output 1 in buffer mode = 10A/15A (360W)
Rated power
360W (at 24Vdc)
240W/360W (buffer mode)
240W/360W (buffer mode)
Output voltage (DC)
22.5Vdc (regulated) in bfr. mode
23Vdc turn-ON
23Vdc turn-ON
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (32Vdc typ. / 35Vdc max.)
Overload / short-circuit current -- min. 17.9A (max. 21A) at load impedance <100mΩ
Do not use the DC-UPS in parallel to increase the output power. However 2 units of the DC-UPS can be paralleled for 1+1 redundancy to gain a higher system reliability.
Overload / short-circuit current -- min. 17.9A (max. 21A) at load impedance <100mΩ
Do not use the DC-UPS in parallel to increase the output power. However 2 units of the DC-UPS can be paralleled for 1+1 redundancy to gain a higher system reliability.
Efficiency
0.978 (24Vdc input)
Mounting mode
DIN rail mounting
Dimensions
W49mm x H124mm x D117mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+50 °C
Visual position indicator
Ready
Buffering
Inhibit
Replace Battery
Buffering
Inhibit
Replace Battery
Current consumption
2A (24Vdc input)
2.7A max. (24Vdc input)
2.7A max. (24Vdc input)
Contents
battery 12V; 17-130Ah
Power dissipation/losses
(24Vdc input; 0A output current) 2.9 W
(24Vdc input; 10A output current) 5.5 W
(24Vdc input; 10A output current) 5.5 W
Manufacturer product status
Commercialized
Equivalent to
UB10242
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
Benefits
Requires Only 1 12V Battery for a 24V Output
Allows Batteries Between 17Ah and 130Ah
Battery Charging with Temperature Tracking
Stable Output Voltage in Buffer Mode
Superior Battery Management for Longest Battery Life
Comprehensive Diagnostic and Monitoring Functions
Replace Battery Signal Included
Electronically Overload and Short Circuit Protected
50% Power Reserves
3 Year warranty
This uninterruptible power supply (UPS) controller UB10.242 is an addition to standard 24V power supplies to bridge power failures of remote or emergency systems which must be kept fully in operation for e.g. 72 hours. The DC-UPS includes an internal temperature sensor and a professional battery management system which charges and monitors the battery to achieve the longest battery service life as well as many diagnostic functions that ensure a reliable operation of the entire system. A unique feature of the UB10 Series is that only 1 12V battery is required to buffer the 24V output. This makes matching batteries unnecessary and allows a precise battery charging and testing.
Allows Batteries Between 17Ah and 130Ah
Battery Charging with Temperature Tracking
Stable Output Voltage in Buffer Mode
Superior Battery Management for Longest Battery Life
Comprehensive Diagnostic and Monitoring Functions
Replace Battery Signal Included
Electronically Overload and Short Circuit Protected
50% Power Reserves
3 Year warranty
This uninterruptible power supply (UPS) controller UB10.242 is an addition to standard 24V power supplies to bridge power failures of remote or emergency systems which must be kept fully in operation for e.g. 72 hours. The DC-UPS includes an internal temperature sensor and a professional battery management system which charges and monitors the battery to achieve the longest battery service life as well as many diagnostic functions that ensure a reliable operation of the entire system. A unique feature of the UB10 Series is that only 1 12V battery is required to buffer the 24V output. This makes matching batteries unnecessary and allows a precise battery charging and testing.
Electrical durability
(at 40°C; 10A output; 24Vdc input) 137400 hours
(at 40°C; 5A output; 24Vdc input) 15years / 131400 hours
(at 25°C; 10A output; 24Vdc input) 15years / 131400 hours
(at 40°C; 5A output; 24Vdc input) 15years / 131400 hours
(at 25°C; 10A output; 24Vdc input) 15years / 131400 hours
Ripple
20mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
886000h (at 40°C; 24Vdc input; MTBF SN 29500 IEC 61709)
1482000h (at 25°C; 24Vdc input; MTBF SN 29500 IEC 61709)
397900h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F)
545000h (at 25°C; 24Vdc input; MTBF MIL HDBK 217F)
1482000h (at 25°C; 24Vdc input; MTBF SN 29500 IEC 61709)
397900h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F)
545000h (at 25°C; 24Vdc input; MTBF MIL HDBK 217F)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - UB10-242-2 - Datasheet.pdf | 01 Oct 2021 | English (US) |