PULS
UB10.245
DC/DC Uninterruptible Power Supply (UPS) control module with external batt. - 50% power reserve - PULS (DIMENSION UB-series) - 22.5Vdc and 12Vdc (regulated) in bfr. mode / 10A / 360W output - with spring-clamp connections - DC input (22.5Vdc-30Vdc (24Vdc nom.)) - DIN rail mounting (mm width) - equivalent to #UB10245
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
UB10.245
Online Price
$630.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
UB10.245
Description
DC/DC Uninterruptible Power Supply (UPS) control module with external batt. - 50% power reserve - PULS (DIMENSION UB-series) - 22.5Vdc and 12Vdc (regulated) in bfr. mode / 10A / 360W output - with spring-clamp connections - DC input (22.5Vdc-30Vdc (24Vdc nom.)) - DIN rail mounting (mm width) - equivalent to #UB10245
Specifications
Primary brand
PULS
Main function
Uninterruptible Power Supply (UPS)
Product series / family name
DIMENSION series
Sub-range name
UB-series
Functions
DC/DC Uninterruptible Power Supply (UPS) control module
Design
external batt.
50% power reserve
Green status LED
50% power reserve
Green status LED
Supply voltage (DC)
22.5Vdc-30Vdc (24Vdc nom.)
Display
"Status" LED
Type of network
DC
Rated current
10A (at 22.5Vdc)
Output 1 in normal mode = 15A
Output 1 in buffer mode = 10A/15A (360W)
Output 2 in normal mode = 12V; 5A
Output 2 in buffer mode = 12V; 5A
Output 1 in normal mode = 15A
Output 1 in buffer mode = 10A/15A (360W)
Output 2 in normal mode = 12V; 5A
Output 2 in buffer mode = 12V; 5A
Rated power
360W (at 24Vdc)
240W/360W (buffer mode)
240W/360W (buffer mode)
Output voltage (DC)
22.5Vdc and 12Vdc (regulated) in bfr. mode
23Vdc turn-ON
23Vdc turn-ON
Connection type
spring-clamp connections
Protection functions
output overvoltage protection (32Vdc typ. / 35Vdc max.)
Overload / short-circuit current -- min. 17.9A (max. 21A) at load impedance <100mΩ
Do not use the DC-UPS in parallel to increase the output power. However 2 units of the DC-UPS can be paralleled for 1+1 redundancy to gain a higher system reliability.
Overload / short-circuit current -- min. 17.9A (max. 21A) at load impedance <100mΩ
Do not use the DC-UPS in parallel to increase the output power. However 2 units of the DC-UPS can be paralleled for 1+1 redundancy to gain a higher system reliability.
Efficiency
0.975 (24Vdc input)
Mounting mode
DIN rail mounting
Dimensions
W49mm x H124mm x D117mm
Material
Aluminium housing
Ambient air temperature for operation
-25...+70 °C
Visual position indicator
Ready
Buffering
Inhibit
Replace Battery
Buffering
Inhibit
Replace Battery
Current consumption
1.1A (24Vdc input)
Contents
battery 12V; 3.9-40Ah
Power dissipation/losses
(No load; 0A output current) 3.4 W
(24Vdc input; 10A output current) 6 W
(24Vdc input; 10A output current) 6 W
Manufacturer product status
Commercialized
Equivalent to
UB10245
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
Benefits
24V DC-UPS With an Additional 12V Output for
Various Applications
Only 1 12V Battery Required
Stable Output Voltage in Buffer Mode
Superior Battery Management for Longest Battery Life
Comprehensive Diagnostic and Monitoring Functions
Replace Battery Signal Included
Electronically Overload and Short Circuit Protected
50% Power Reserves
3 Year warranty
The UB10.245 uninterruptible power supply (UPS) controller along with a standard 24V power supply and 1 12V battery can bridge power failures or voltage fluctuations. This unit can supply and bridge both a 24V load as well as a 12V load at the same time. The 12V is generated by a DC/DC converter from the 24V output. Therefore systems that utilize 24V control circuits and require 12V for e.g. remote radio telemetry can be supplied with only 1 UB10.245 DC-UPS controller. The DC-UPS includes a professional battery management system which charges and monitors the battery to achieve the longest battery service life as well as many diagnostic functions that ensure a reliable operation of the entire system.
Various Applications
Only 1 12V Battery Required
Stable Output Voltage in Buffer Mode
Superior Battery Management for Longest Battery Life
Comprehensive Diagnostic and Monitoring Functions
Replace Battery Signal Included
Electronically Overload and Short Circuit Protected
50% Power Reserves
3 Year warranty
The UB10.245 uninterruptible power supply (UPS) controller along with a standard 24V power supply and 1 12V battery can bridge power failures or voltage fluctuations. This unit can supply and bridge both a 24V load as well as a 12V load at the same time. The 12V is generated by a DC/DC converter from the 24V output. Therefore systems that utilize 24V control circuits and require 12V for e.g. remote radio telemetry can be supplied with only 1 UB10.245 DC-UPS controller. The DC-UPS includes a professional battery management system which charges and monitors the battery to achieve the longest battery service life as well as many diagnostic functions that ensure a reliable operation of the entire system.
Electrical durability
(at 40°C; 10A output; 24Vdc input) 114000 hours
(at 40°C; 5A output; 24Vdc input) 148000 hours
(at 25°C; 10A output; 24Vdc input) 380000 hours
(at 40°C; 5A output; 24Vdc input) 148000 hours
(at 25°C; 10A output; 24Vdc input) 380000 hours
Ripple
20mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
788000h (at 40°C; 24Vdc input; MTBF SN 29500 IEC 61709)
343000h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F)
343000h (at 40°C; 24Vdc input; MTBF MIL HDBK 217F)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - UB10-245-2 - Datasheet.pdf | 01 Oct 2021 | English (US) |